Contemporary Certified Passivhaus, London
A contemporary Passivhaus certified home in east London built with CLT.
![Contemporary Certified Passivhaus, London](/images/media/projects/lansdowne%20drive/front_D-crop.jpg?q=92&fm=webp&w=1280)
![](/images/media/projects/lansdowne%20drive/rear4-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/RM_rear1-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/1.d-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/1.e-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/2e-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/2f-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/2j-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/2i-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/2g-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/2h-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/2a-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/2b-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/1.f-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/1.g-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/AS_Lansdowne_152016-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/AS_Lansdowne_152082-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/AS_Lansdowne_151921_fin-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/AS_Lansdowne_152026-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/AW_MG_9994-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/AW_MG_0010-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/AW_MG_9904-crop.jpg?q=92&fm=webp&w=600)
![](/images/media/projects/lansdowne%20drive/front_D-crop.jpg?q=92&fm=webp&w=800)
![](/images/media/projects/lansdowne%20drive/rear4-crop.jpg?q=92&fm=webp&w=1000)
Architect
Bernard Tulkens - Tectonics Architects
Accredited Passivhaus Designer
Peter Rankin
Airtight Result
0.29 ac/h @ 50 Pa
U Value Roof
0.08W/m²K
U Value Upper Wall
0.10 W/m²K
U Value Lower Wall
0.13 W/m²K
U Value Ground Floor
0.09 W/m²K
Annual Heating Demand
14 Kwh/m²/yr (Est. heating bill is £170 per year)